Place of Origin: | Guangdong, China (Mainland) |
---|---|
Brand Name: | HAIDA |
Certification: | CE,ISO |
Model Number: | HD-W810-1 |
Minimum Order Quantity: | 1 Set |
Price: | Negotiable |
Packaging Details: | ach set protected with resin fiber and PP film, then put into Strong wooden case with operation man |
Delivery Time: | 20 days after order confirmed |
Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash, escrow |
Supply Ability: | 30 Sets per Month Haida |
Power: | Electronic | Working Temperature: | 0-50 ℃ |
---|---|---|---|
Cabinet Negative Pressure: | > 120Pa | Pressure Cabinet: | ≥5m3 / Min |
Instrument Noise: | <65dB (A) | Machine Weight: | About 150kg |
Power Supply: | AC220V ± 10%, 50Hz | Power Consumption: | <1500W |
High Light: | ISO Approve bacterial filtration efficiency test equipment,1500W bacterial filtration efficiency test equipment,ISO Approve bacterial filtration efficiency test apparatus |
ISO Approve Bacterial Filtration Efficiency Test Equipment For Face Mask 1500W
Usage
Bacterial Filtration Efficiency Test Equipment is used to detect various medical and daily protective mask materials and filter out the percentage of bacteria-containing suspended particles (BFE) under the specified flow rate.
It is suitable for the performance testing of bacterial filtration efficiency of medical surgical masks by metrological inspection departments, scientific research institutes, medical mask manufacturers and other related departments.
Test standard
YY0469-2004,YY/T 0969-2013,ASTMF2100,ASTMF2101,EN14683 ect.
Technical parameters
Technical Index | HD-W810-1 |
Sampling flow | 28.3L / min, resolution: 0.1L / min, accuracy: ± 2.5% |
Spray flow | 8 ~10L / min, resolution: 0.1L / min, accuracy: ± 5% |
Peristaltic pump flow | 0.006 ~3.0ml / min, resolution: 0.001ml / min, accuracy: ± 2% |
Pressure before sampling flowmeter | -20 ~0KPa resolution: 0.01KPa, accuracy: ± 2% |
Front pressure of spray flow meter | 0 ~300KPa, resolution: 0.1KPa, accuracy: ± 2% |
Aerosol chamber negative pressure | -90 ~-120Pa, resolution: 0.1Pa, accuracy: ± 1% |
Cabinet negative pressure | > 120Pa |
Data storage capacity | > 500000 sets, capacity can be expanded |
High-efficiency air filtration performance |
The filtration efficiency of particles above 0.3um is ≥99.995%, |
Median mass diameter of aerosol generator | 3.0 ± 0.3μm, geometric standard deviation ≤1.5 |
Dual 6-stage Anderson sampler capture particle size |
I> 7μm, II>4.7-7μm, III >3.3-4.7μm, IV >2.1-3.3μm, V> 1.1-2.1μm, VI >0.6-1.1 μm |
Aerosol chamber specifications | 60cmX8.5 cmX 3cm (LxWxH) |
Total number of positive control sampler particles | 2200 ± 500cfu |
Ventilation flow of negative pressure cabinet | ≥5m3 / min |
Negative pressure cabinet door size | 1000 X 730mm |
Host size | 1180 X 650 X1300mm (WxDxH) |
Bracket size | 1180 X 650 X 600mm (WxDxH), height adjustable within 10 cm |